1.1
This standard applies to centrifugal pumps that require a driver-rated output of 373 W (1/2 hp) nominal up to and including 7.46 kW (10 hp) nominal.

1.2
This Standard specifies the method for testing centrifugal pumps to determine the following characteristics:

(a) the total head produced by the pump versus the pump rate of flow;
(b) input power versus pump rate of flow; and
(c) efficiency versus pump rate of flow.

1.3
This Standard does not apply to centrifugal pumps for the following services:

(a) decorative fountain pumps;
(b) fire pumps as defined in NFPA Standard 20;
(c) hydromassage pumps as defined and installed in accordance with CSA Standard C22.2 No. 218.2;
(d) jet pumps;
(e) multi-stage pumps;
(f) recreational vehicle pumps;
(g) seal-less pumps;
(h) solids-handling pumps;
(i) sprinkler pumps for residential lawn watering applications;
(j) deep well submersible pumps;
(k) submersible-type effluent pumps up to and including 1.49 kW (2 hp);
(l) submersible-and column-type sump pumps for residential applications; and
(m) utility or contractor pumps.

1.4
This Standard does not cover the measurement of motor efficiency, nor does it specify the minimum efficiency required of the motor used to drive a pump, whether the motor is a separate motor coupled to the pump or is mounted on a common shaft with the pump.
Note: For motor efficiency measurements, refer to CSA Standards C390 and CAN/CSA-C747.

1.5
The values given in SI (metric) units are the standard. The values given in parentheses are for information only.
Edition : 1
File Size : 1 file , 570 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 14
Product Code(s) : 2415373, 2415871, 2415373
Published : 04/05/2002

History

CAN/CSA C820-02 (R2012)
Published Date: 04/05/2002
Energy Efficiency Test Methods for Small Pumps
$24.3

Related products

CAN/CSA C860-11 (R2020)
Published Date: 02/01/2011
Performance of Internally Lighted Exit Signs, Includes Update No. 1 (2011)
$50.4
CAN/CSA C191-13 (R2022)
Published Date: 03/01/2013
Performance of Electric Storage Tank Water Heaters for Domestic Hot Water Service
$77.4
CAN/CSA C875-13 (R2023)
Published Date: 09/01/2013
Performance of general service directional lamps
$47.4

Best-Selling Products

NZS 10011
Published Date:
Guidelines for auditing quality systems
NZS 1011:1964
Published Date:
Methods for bend testing of metals
NZS 1153
Published Date:
Specification for screw gauge limits and tolerances
NZS 1188:1954
Published Date:
Fire-doors and fire-windows
NZS 1227
Published Date:
Specification for Unified screw threads
NZS 1340:1970
Published Date:
Thermal insulating materials for buildings